189 8069 5689

Oracle小型机T7-1更换rpool中的硬盘-创新互联

  1. 确定故障原因

    成都创新互联公司专注于石峰企业网站建设,成都响应式网站建设,电子商务商城网站建设。石峰网站建设公司,为石峰等地区提供建站服务。全流程按需网站建设,专业设计,全程项目跟踪,成都创新互联公司专业和态度为您提供的服务
root@test # fmadm faulty
--------------- ------------------------------------  -------------- ---------
TIME            EVENT-ID                              MSG-ID         SEVERITY
--------------- ------------------------------------  -------------- ---------
Oct 30 22:11:10 8ad90d8d-3e4f-432d-a233-84f8627dcf10  DISK-8000-0X   Major    

Problem Status    : open
Diag Engine       : eft / 1.16
System
    Manufacturer  : Oracle Corporation
    Name          : SPARC T7-1
    Part_Number   : 34429612+1+1
    Serial_Number : AK00373594
    Host_ID       : 86bb603a

----------------------------------------
Suspect 1 of 1 :
   Problem class : fault.io.disk.predictive-failure
   Certainty   : 100%
   Affects     : dev:///:devid=id1,sd@n5000cca02f1d2524//scsi_vhci/disk@g5000cca02f1d2524
   Status      : faulted but still providing degraded service

   FRU
     Status           : faulty
     Location         : "/SYS/DBP/HDD0"
     Manufacturer     : HGST
     Name             : H101860SFSUN600G
     Part_Number      : HGST-H101860SFSUN600G
     Revision         : A990
     Serial_Number    : 001619FJ0WNC--------03GJ0WNC
     Chassis
        Manufacturer  : Oracle Corporation
        Name          : SPARC T7-1
        Part_Number   : 34429612+1+1
        Serial_Number : AK00373594

Description : SMART health-monitoring firmware reported that a disk failure is
              imminent.

Response    : A hot-spare disk may have been activated.

Impact      : It is likely that the continued operation of this disk will
              result in data loss.

Action      : Use 'fmadm faulty' to provide a more detailed view of this event.
              Please refer to the associated reference document at
              http://support.oracle.com/msg/DISK-8000-0X for the latest service
              procedures and policies regarding this diagnosis.
root@test # more /var/adm/messages 
Nov  8 16:23:13 zbwl03 scsi: [ID 243001 kern.warning] WARNING: /scsi_vhci/disk@g5000cca02f1d2524 (sd5):
Nov  8 16:23:13 zbwl03  Error for Command: read(10)                Error Level: Informational
Nov  8 16:23:13 zbwl03 scsi: [ID 243001 kern.info]      Requested Block: 394604487                 Error Block: 394604487
Nov  8 16:23:13 zbwl03 scsi: [ID 243001 kern.info]      Vendor: HGST                               Serial Number: 1619FJ0WNC  
Nov  8 16:23:13 zbwl03 scsi: [ID 243001 kern.info]      Sense Key: Soft_Error
Nov  8 16:23:13 zbwl03 scsi: [ID 243001 kern.info]      ASC: 0x5d (), ASCQ: 0x90, FRU: 0x90
Nov  8 17:06:27 zbwl03 scsi: [ID 243001 kern.warning] WARNING: /scsi_vhci/disk@g5000cca02f1d2524 (sd5):
Nov  8 17:06:27 zbwl03  Error for Command: read(10)                Error Level: Informational
Nov  8 17:06:27 zbwl03 scsi: [ID 243001 kern.info]      Requested Block: 118860647                 Error Block: 118860647
Nov  8 17:06:27 zbwl03 scsi: [ID 243001 kern.info]      Vendor: HGST                               Serial Number: 1619FJ0WNC  
Nov  8 17:06:27 zbwl03 scsi: [ID 243001 kern.info]      Sense Key: Soft_Error
Nov  8 17:06:27 zbwl03 scsi: [ID 243001 kern.info]      ASC: 0x5d (), ASCQ: 0x90, FRU: 0x90
Nov  8 17:11:11 zbwl03 scsi: [ID 243001 kern.warning] WARNING: /scsi_vhci/disk@g5000cca02f1d2524 (sd5):
Nov  8 17:11:11 zbwl03  Error for Command: read(10)                Error Level: Informational
Nov  8 17:11:11 zbwl03 scsi: [ID 243001 kern.info]      Requested Block: 86417744                  Error Block: 86417744
Nov  8 17:11:11 zbwl03 scsi: [ID 243001 kern.info]      Vendor: HGST                               Serial Number: 1619FJ0WNC  
Nov  8 17:11:11 zbwl03 scsi: [ID 243001 kern.info]      Sense Key: Soft_Error
Nov  8 17:11:11 zbwl03 scsi: [ID 243001 kern.info]      ASC: 0x5d (), ASCQ: 0x90, FRU: 0x90
Nov  8 17:36:14 zbwl03 scsi: [ID 243001 kern.warning] WARNING: /scsi_vhci/disk@g5000cca02f1d2524 (sd5):
Nov  8 17:36:14 zbwl03  Error for Command: read(10)                Error Level: Informational
Nov  8 17:36:14 zbwl03 scsi: [ID 243001 kern.info]      Requested Block: 118915795                 Error Block: 118915795
Nov  8 17:36:14 zbwl03 scsi: [ID 243001 kern.info]      Vendor: HGST                               Serial Number: 1619FJ0WNC  
Nov  8 17:36:14 zbwl03 scsi: [ID 243001 kern.info]      Sense Key: Soft_Error
Nov  8 17:36:14 zbwl03 scsi: [ID 243001 kern.info]      ASC: 0x5d (), ASCQ: 0x90, FRU: 0x90
Nov  8 17:54:11 zbwl03 scsi: [ID 243001 kern.warning] WARNING: /scsi_vhci/disk@g5000cca02f1d2524 (sd5):
Nov  8 17:54:11 zbwl03  Error for Command: read(10)                Error Level: Informational
Nov  8 17:54:11 zbwl03 scsi: [ID 243001 kern.info]      Requested Block: 86417744                  Error Block: 86417744
Nov  8 17:54:11 zbwl03 scsi: [ID 243001 kern.info]      Vendor: HGST                               Serial Number: 1619FJ0WNC  
Nov  8 17:54:11 zbwl03 scsi: [ID 243001 kern.info]      Sense Key: Soft_Error
Nov  8 17:54:11 zbwl03 scsi: [ID 243001 kern.info]      ASC: 0x5d (), ASCQ: 0x90, FRU: 0x90
Nov  8 19:11:49 zbwl03 scsi: [ID 243001 kern.warning] WARNING: /scsi_vhci/disk@g5000cca02f1d2524 (sd5):
Nov  8 19:11:49 zbwl03  Error for Command: read(10)                Error Level: Informational
Nov  8 19:11:49 zbwl03 scsi: [ID 243001 kern.info]      Requested Block: 211206686                 Error Block: 211206686
Nov  8 19:11:49 zbwl03 scsi: [ID 243001 kern.info]      Vendor: HGST                               Serial Number: 1619FJ0WNC  
Nov  8 19:11:49 zbwl03 scsi: [ID 243001 kern.info]      Sense Key: Soft_Error
Nov  8 19:11:49 zbwl03 scsi: [ID 243001 kern.info]      ASC: 0x5d (), ASCQ: 0x90, FRU: 0x90
Nov  8 20:16:45 zbwl03 scsi: [ID 243001 kern.warning] WARNING: /scsi_vhci/disk@g5000cca02f1d2524 (sd5):
Nov  8 20:16:45 zbwl03  Error for Command: read(10)                Error Level: Informational
Nov  8 20:16:45 zbwl03 scsi: [ID 243001 kern.info]      Requested Block: 213848167                 Error Block: 213848167
Nov  8 20:16:45 zbwl03 scsi: [ID 243001 kern.info]      Vendor: HGST                               Serial Number: 1619FJ0WNC  
Nov  8 20:16:45 zbwl03 scsi: [ID 243001 kern.info]      Sense Key: Soft_Error
Nov  8 20:16:45 zbwl03 scsi: [ID 243001 kern.info]      ASC: 0x5d (), ASCQ: 0x90, FRU: 0x90
Nov  8 20:21:55 zbwl03 scsi: [ID 243001 kern.warning] WARNING: /scsi_vhci/disk@g5000cca02f1d2524 (sd5):
Nov  8 20:21:55 zbwl03  Error for Command: read(10)                Error Level: Informational
Nov  8 20:21:55 zbwl03 scsi: [ID 243001 kern.info]      Requested Block: 209782185                 Error Block: 209782185
Nov  8 20:21:55 zbwl03 scsi: [ID 243001 kern.info]      Vendor: HGST                               Serial Number: 1619FJ0WNC  
Nov  8 20:21:55 zbwl03 scsi: [ID 243001 kern.info]      Sense Key: Soft_Error
Nov  8 20:21:55 zbwl03 scsi: [ID 243001 kern.info]      ASC: 0x5d (), ASCQ: 0x90, FRU: 0x90
Nov  8 20:27:08 zbwl03 scsi: [ID 243001 kern.warning] WARNING: /scsi_vhci/disk@g5000cca02f1d2524 (sd5):
Nov  8 20:27:08 zbwl03  Error for Command: read(10)                Error Level: Informational
Nov  8 20:27:08 zbwl03 scsi: [ID 243001 kern.info]      Requested Block: 213848182                 Error Block: 213848182
Nov  8 20:27:08 zbwl03 scsi: [ID 243001 kern.info]      Vendor: HGST                               Serial Number: 1619FJ0WNC  
Nov  8 20:27:08 zbwl03 scsi: [ID 243001 kern.info]      Sense Key: Soft_Error
Nov  8 20:27:08 zbwl03 scsi: [ID 243001 kern.info]      ASC: 0x5d (), ASCQ: 0x90, FRU: 0x90
Nov  8 20:37:29 zbwl03 scsi: [ID 243001 kern.warning] WARNING: /scsi_vhci/disk@g5000cca02f1d2524 (sd5):
Nov  8 20:37:29 zbwl03  Error for Command: read(10)                Error Level: Informational
Nov  8 20:37:29 zbwl03 scsi: [ID 243001 kern.info]      Requested Block: 211019254                 Error Block: 211019254
Nov  8 20:37:29 zbwl03 scsi: [ID 243001 kern.info]      Vendor: HGST                               Serial Number: 1619FJ0WNC  
Nov  8 20:37:29 zbwl03 scsi: [ID 243001 kern.info]      Sense Key: Soft_Error
Nov  8 20:37:29 zbwl03 scsi: [ID 243001 kern.info]      ASC: 0x5d (), ASCQ: 0x90, FRU: 0x90
Nov  8 20:42:42 zbwl03 scsi: [ID 243001 kern.warning] WARNING: /scsi_vhci/disk@g5000cca02f1d2524 (sd5):
Nov  8 20:42:42 zbwl03  Error for Command: read(10)                Error Level: Informational
Nov  8 20:42:42 zbwl03 scsi: [ID 243001 kern.info]      Requested Block: 211955388                 Error Block: 211955388
Nov  8 20:42:42 zbwl03 scsi: [ID 243001 kern.info]      Vendor: HGST                               Serial Number: 1619FJ0WNC  
Nov  8 20:42:42 zbwl03 scsi: [ID 243001 kern.info]      Sense Key: Soft_Error
Nov  8 20:42:42 zbwl03 scsi: [ID 243001 kern.info]      ASC: 0x5d (), ASCQ: 0x90, FRU: 0x90
Nov  8 20:58:15 zbwl03 scsi: [ID 243001 kern.warning] WARNING: /scsi_vhci/disk@g5000cca02f1d2524 (sd5):
Nov  8 20:58:15 zbwl03  Error for Command: read(10)                Error Level: Informational
Nov  8 20:58:15 zbwl03 scsi: [ID 243001 kern.info]      Requested Block: 213894761                 Error Block: 213894761
Nov  8 20:58:15 zbwl03 scsi: [ID 243001 kern.info]      Vendor: HGST                               Serial Number: 1619FJ0WNC  
Nov  8 20:58:15 zbwl03 scsi: [ID 243001 kern.info]      Sense Key: Soft_Error
Nov  8 20:58:15 zbwl03 scsi: [ID 243001 kern.info]      ASC: 0x5d (), ASCQ: 0x90, FRU: 0x90
Nov  8 21:08:38 zbwl03 scsi: [ID 243001 kern.warning] WARNING: /scsi_vhci/disk@g5000cca02f1d2524 (sd5):
                            Serial Number: 1619FJ0WNC 
root@test # zpool status rpool
  pool: rpool
 state: DEGRADED
status: One or more devices are unavailable in response to persistent errors.
        Sufficient replicas exist for the pool to continue functioning in a
        degraded state.
action: Determine if the device needs to be replaced, and clear the errors
        using 'zpool clear' or 'fmadm repaired', or replace the device
        with 'zpool replace'.
        Run 'zpool status -v' to see device specific details.
  scan: resilvered 191G in 18m17s with 0 errors on Wed Aug 31 20:15:31 2016

config:

        NAME                       STATE     READ WRITE CKSUM
        rpool                      DEGRADED     0     0     0
          mirror-0                 DEGRADED     0     0     0
            c0t5000CCA02F1D2524d0  DEGRADED     0     0     0
            c0t5000CCA02F1D7534d0  ONLINE       0     0     0

errors: No known data errors

  2.具体操作步骤

root@test # zpool offline rpool c0t5000CCA02F1D2524d0
root@test # zpool status rpool
  pool: rpool
 state: DEGRADED
status: One or more devices has been taken offline by the administrator.
        Sufficient replicas exist for the pool to continue functioning in a
        degraded state.
action: Online the device using 'zpool online' or replace the device with
        'zpool replace'.
  scan: resilvered 191G in 18m17s with 0 errors on Wed Aug 31 20:15:31 2016

config:

        NAME                       STATE     READ WRITE CKSUM
        rpool                      DEGRADED     0     0     0
          mirror-0                 DEGRADED     0     0     0
            c0t5000CCA02F1D2524d0  OFFLINE      0     0     0
            c0t5000CCA02F1D7534d0  ONLINE       0     0     0

errors: No known data errors
root@test # cfgadm -al
Ap_Id                          Type         Receptacle   Occupant     Condition
c4                             fc           connected    unconfigured unknown
c5                             fc-fabric    connected    configured   unknown
c5::2100000e1ecb1261           unknown      connected    unconfigured unknown
c5::2100000e1ecc7100           disk         connected    configured   unknown
c5::2100000e1ecc8320           disk         connected    configured   unknown
c6                             scsi-sas     connected    unconfigured unknown
c7                             scsi-sas     connected    configured   unknown
c7::w5000cca02f1d2524,0        disk-path    connected    configured   unknown
c8                             scsi-sas     connected    configured   unknown
c8::w5000cca02f1d7535,0        disk-path    connected    configured   unknown
c9                             fc           connected    unconfigured unknown
c11                            fc-fabric    connected    configured   unknown
c11::2100000e1ecb11f1          unknown      connected    unconfigured unknown
c11::2100000e1ecc8350          disk         connected    configured   unknown
c11::2100000e1ecc84c0          disk         connected    configured   unknown
usb0/1                         unknown      empty        unconfigured ok
usb0/2                         unknown      empty        unconfigured ok
usb0/3                         usb-hub      connected    configured   ok
usb0/3.1                       usb-device   connected    configured   ok
usb0/3.2                       usb-communications connected    configured   ok
usb0/3.3                       unknown      empty        unconfigured ok
usb0/3.4                       unknown      empty        unconfigured ok
usb0/4                         usb-hub      connected    configured   ok
usb0/4.1                       unknown      empty        unconfigured ok
usb0/4.2                       usb-storage  connected    configured   ok
usb0/5                         unknown      empty        unconfigured ok
usb0/6                         unknown      empty        unconfigured ok
usb0/7                         usb-hub      connected    configured   ok
usb0/7.1                       unknown      empty        unconfigured ok
usb0/7.2                       unknown      empty        unconfigured ok
usb0/7.3                       unknown      empty        unconfigured ok
usb0/7.4                       unknown      empty        unconfigured ok
usb0/8                         usb-hub      connected    configured   ok
usb0/8.1                       usb-device   connected    configured   ok
usb0/8.2                       unknown      empty        unconfigured ok

记住位置编号,unconfigure故障磁盘

c7::w5000cca02f1d2524,0
root@test # cfgadm -c unconfigure  c7::w5000cca02f1d2524,0

拨出故障硬盘,插入新的磁盘

root@test # cfgadm -al
Ap_Id                          Type         Receptacle   Occupant     Condition
c4                             fc           connected    unconfigured unknown
c5                             fc-fabric    connected    configured   unknown
c5::2100000e1ecb1261           unknown      connected    unconfigured unknown
c5::2100000e1ecc7100           disk         connected    configured   unknown
c5::2100000e1ecc8320           disk         connected    configured   unknown
c6                             scsi-sas     connected    unconfigured unknown
c7                             scsi-sas     connected    configured   unknown
c7::w5000cca02f1091b9,0        disk-path    connected    configured   unknown
c8                             scsi-sas     connected    configured   unknown
c8::w5000cca02f1d7535,0        disk-path    connected    configured   unknown
c9                             fc           connected    unconfigured unknown
c11                            fc-fabric    connected    configured   unknown
c11::2100000e1ecb11f1          unknown      connected    unconfigured unknown
c11::2100000e1ecc8350          disk         connected    configured   unknown
c11::2100000e1ecc84c0          disk         connected    configured   unknown
usb0/1                         unknown      empty        unconfigured ok
usb0/2                         unknown      empty        unconfigured ok
usb0/3                         usb-hub      connected    configured   ok
usb0/3.1                       usb-device   connected    configured   ok
usb0/3.2                       usb-communications connected    configured   ok
usb0/3.3                       unknown      empty        unconfigured ok
usb0/3.4                       unknown      empty        unconfigured ok
usb0/4                         usb-hub      connected    configured   ok
usb0/4.1                       unknown      empty        unconfigured ok
usb0/4.2                       usb-storage  connected    configured   ok
usb0/5                         unknown      empty        unconfigured ok
usb0/6                         unknown      empty        unconfigured ok
usb0/7                         usb-hub      connected    configured   ok
usb0/7.1                       unknown      empty        unconfigured ok
usb0/7.2                       unknown      empty        unconfigured ok
usb0/7.3                       unknown      empty        unconfigured ok
usb0/7.4                       unknown      empty        unconfigured ok
usb0/8                         usb-hub      connected    configured   ok
usb0/8.1                       usb-device   connected    configured   ok
usb0/8.2                       unknown      empty        unconfigured ok
root@test # cfgadm -c configure  c7::w5000cca02f1091b9,0
root@test # format
Searching for disks...done


AVAILABLE DISK SELECTIONS:
       0. c0t5000CCA02F1091B8d0   solaris
          /scsi_vhci/disk@g5000cca02f1091b8
          /dev/chassis/SYS/DBP/HDD0/disk
       1. c0t5000CCA02F1D7534d0 
          /scsi_vhci/disk@g5000cca02f1d7534
          /dev/chassis/SYS/DBP/HDD1/disk
       2. c2t0d0 
          /pci@300/pci@2/usb@0/hub@4/storage@2/disk@0,0
          /dev/chassis/SYS/MB/EUSB-DISK/disk
       3. c0t6000B08414B303033373335353600004d0 
          /scsi_vhci/ssd@g6000b08414b303033373335353600004
       4. c0t6000B08414B303033373335353600005d0 
          /scsi_vhci/ssd@g6000b08414b303033373335353600005
       5. c0t6000B08414B303033373335353600003d0 
          /scsi_vhci/ssd@g6000b08414b303033373335353600003
       6. c0t6000B08414B303033373335353600000d0 
          /scsi_vhci/ssd@g6000b08414b303033373335353600000
       7. c0t6000B08414B303033373335353600001d0 
          /scsi_vhci/ssd@g6000b08414b303033373335353600001
       8. c0t6000B08414B303033373335353600002d0 
          /scsi_vhci/ssd@g6000b08414b303033373335353600002
       9. c0t6000B08414B303033373335353600006d0 
          /scsi_vhci/ssd@g6000b08414b303033373335353600006
Specify disk (enter its number): ^C
root@test # zpool help replace
usage:
        replace [-f]   [new-device]
root@test # zpool replace rpool c0t5000CCA02F1D2524d0 c0t5000CCA02F1091B8d0
Make sure to wait until resilver is done before rebooting.
root@zbwl03 # zpool status rpool
  pool: rpool
 state: DEGRADED
status: One or more devices is currently being resilvered.  The pool will
        continue to function in a degraded state.
action: Wait for the resilver to complete.
        Run 'zpool status -v' to see device specific details.
  scan: resilver in progress since Tue Nov 14 10:38:00 2017
    74.5G scanned out of 165G at 2.87G/s, 31s to go
    0 resilvered
config:

        NAME                         STATE     READ WRITE CKSUM
        rpool                        DEGRADED     0     0     0
          mirror-0                   DEGRADED     0     0     0
            replacing-0              DEGRADED     0     0     0
              c0t5000CCA02F1D2524d0  OFFLINE      0     0     0
              c0t5000CCA02F1091B8d0  DEGRADED     0     0     0  (resilvering)
            c0t5000CCA02F1D7534d0    ONLINE       0     0     0

errors: No known data errors
root@test # zpool status rpool
  pool: rpool
 state: DEGRADED
status: One or more devices is currently being resilvered.  The pool will
        continue to function in a degraded state.
action: Wait for the resilver to complete.
        Run 'zpool status -v' to see device specific details.
  scan: resilver in progress since Tue Nov 14 10:38:00 2017
    165G scanned
    34.4G resilvered at 183M/s, 20.91% done, 12m08s to go
config:

        NAME                         STATE     READ WRITE CKSUM
        rpool                        DEGRADED     0     0     0
          mirror-0                   DEGRADED     0     0     0
            replacing-0              DEGRADED    14     0     0
              c0t5000CCA02F1D2524d0  OFFLINE      0     0     0
              c0t5000CCA02F1091B8d0  DEGRADED     0     0     0  (resilvering)
            c0t5000CCA02F1D7534d0    ONLINE       0     0     0

errors: No known data errors
root@test # zpool status rpool
  pool: rpool
 state: DEGRADED
status: One or more devices is currently being resilvered.  The pool will
        continue to function in a degraded state.
action: Wait for the resilver to complete.
        Run 'zpool status -v' to see device specific details.
  scan: resilver in progress since Tue Nov 14 10:38:00 2017
    165G scanned
    161G resilvered at 157M/s, 97.98% done, 21s to go
config:

        NAME                         STATE     READ WRITE CKSUM
        rpool                        DEGRADED     0     0     0
          mirror-0                   DEGRADED     0     0     0
            replacing-0              DEGRADED    14     0     0
              c0t5000CCA02F1D2524d0  OFFLINE      0     0     0
              c0t5000CCA02F1091B8d0  DEGRADED     0     0     0  (resilvering)
            c0t5000CCA02F1D7534d0    ONLINE       0     0     0

errors: No known data errors
root@test # zpool status rpool
  pool: rpool
 state: DEGRADED
  scan: resilvered 165G in 19m26s with 0 errors on Tue Nov 14 10:57:26 2017

config:

        NAME                         STATE     READ WRITE CKSUM
        rpool                        DEGRADED     0     0     0
          mirror-0                   DEGRADED     0     0     0
            replacing-0              DEGRADED    14     0     0
              c0t5000CCA02F1D2524d0  OFFLINE      0     0     0
              c0t5000CCA02F1091B8d0  ONLINE       0     0     0
            c0t5000CCA02F1D7534d0    ONLINE       0     0     0

errors: No known data errors
root@test # zpool status rpool
  pool: rpool
 state: ONLINE
  scan: resilvered 165G in 19m26s with 0 errors on Tue Nov 14 10:57:26 2017

config:

        NAME                       STATE     READ WRITE CKSUM
        rpool                      ONLINE       0     0     0
          mirror-0                 ONLINE       0     0     0
            c0t5000CCA02F1091B8d0  ONLINE       0     0     0
            c0t5000CCA02F1D7534d0  ONLINE       0     0     0

errors: No known data errors
root@test #

另外有需要云服务器可以了解下创新互联scvps.cn,海内外云服务器15元起步,三天无理由+7*72小时售后在线,公司持有idc许可证,提供“云服务器、裸金属服务器、高防服务器、香港服务器、美国服务器、虚拟主机、免备案服务器”等云主机租用服务以及企业上云的综合解决方案,具有“安全稳定、简单易用、服务可用性高、性价比高”等特点与优势,专为企业上云打造定制,能够满足用户丰富、多元化的应用场景需求。


网站名称:Oracle小型机T7-1更换rpool中的硬盘-创新互联
标题网址:http://cdxtjz.cn/article/jeooo.html

其他资讯